3-9 Programming
Programming Level
Normal
Display Operator Setup Master
Can Be Enabled By…
Keypad Terminal --- Yes (E2) No Yes (E1)
Password --- Yes Yes Yes
Menu Item Access
Password Enter Enter Enter Program
Setpoints View Program
1
Program Program
Setup Menu
Default Program View Program
1
Program Program
Timed Outputs View Program
1
Program Program
Speed Comp View Program
1
Program Program
Offset View Program
1
Program Program
Motion Detect View Program
1
Program Program
Analog Output View Program
1
Program Program
Pulse Copy View --- Program Program
CHN Copy View --- Program Program
PGM Copy View --- Program Program
I/O Status Menu
Input Status View View View View
Output Status View View View View
System Info Menu
Setpoint Use View View View View
Software Version View View View View
Model & Options View View View View
Config Menu
Hardware Menu
Keyboard Qty --- --- --- Program
2
Increasing Dir --- --- --- Program
Scale Factor --- --- --- Program
Shaft Position --- --- --- Program
Analog Qty --- --- --- Program
Resolver Type --- --- --- Program
Pgm Sel Mode --- --- --- Program
Display Menu
Rate Setup --- --- --- Program
Toggle RPM --- --- --- Program
RPM Update --- --- --- Program
Spd Comp Mode --- --- --- Program
Grp Pos Disp --- --- --- Program
Pgm Enable Menu
Enable Codes --- --- --- Program
Per Chn Enable --- --- --- Program
Enable Options
Setpoints --- --- --- Program
Default Program --- --- --- Program
Speed Comp --- --- --- Program
Timed Outputs --- --- --- Program
Offsets --- --- --- Program
Motion Detect --- --- --- Program
Analog Output --- --- --- Program
Chn ANDing Menu
Motion ANDing --- --- --- Program
Outp Enab AND --- --- --- Program
Output Groups --- --- --- Program
Communications --- --- --- Program
Test Menu
Memory Tests --- --- --- Run
Enable Codes (cont’d)
Figure 21—Programming Access
Levels for Various Menu Items
1
Can be programmed only if specified through PER CHN ENABLE and ENABLE OPTIONS.
2
KEYBOARD QTY can be programmed only through the keypad whose address is “0.” See Figure 14.